Uncategorized

Get e-book Physico-Chemistry of Solid-Gas Interfaces: Concepts and Methodology for Gas Sensor Development (Iste)

Free download. Book file PDF easily for everyone and every device. You can download and read online Physico-Chemistry of Solid-Gas Interfaces: Concepts and Methodology for Gas Sensor Development (Iste) file PDF Book only if you are registered here. And also you can download or read online all Book PDF file that related with Physico-Chemistry of Solid-Gas Interfaces: Concepts and Methodology for Gas Sensor Development (Iste) book. Happy reading Physico-Chemistry of Solid-Gas Interfaces: Concepts and Methodology for Gas Sensor Development (Iste) Bookeveryone. Download file Free Book PDF Physico-Chemistry of Solid-Gas Interfaces: Concepts and Methodology for Gas Sensor Development (Iste) at Complete PDF Library. This Book have some digital formats such us :paperbook, ebook, kindle, epub, fb2 and another formats. Here is The CompletePDF Book Library. It's free to register here to get Book file PDF Physico-Chemistry of Solid-Gas Interfaces: Concepts and Methodology for Gas Sensor Development (Iste) Pocket Guide.

Figure 5. Figure 6. Different types of columns can be applied for different fields. Depending on the type of sample, some GC columns are better than the others. It produces fast run times with baseline resolution of key components in under 3 minutes. Moreover, it displays enhanced resolutions of ethanol and acetone peaks, which helps with determining the BAC levels. This particular column is known as Zebron-BAC and it made with polyimide coating on the outside and the inner layer is made of fused silica and the inner diameter ranges from.

There are also many other Zebron brand columns designed for other purposes. Another example of a Zebron GC column is known as the Zebron-inferno. Its outer layer is coated with a special type of polyimide that is designed to withstand high temperatures. As shown in figure 6, it contains an extra layer inside. Moreover, it is also used for acidic and basic samples. The detector is the device located at the end of the column which provides a quantitative measurement of the components of the mixture as they elute in combination with the carrier gas.

In theory, any property of the gaseous mixture that is different from the carrier gas can be used as a detection method. These detection properties fall into two categories: bulk properties and specific properties. Bulk properties, which are also known as general properties, are properties that both the carrier gas and analyte possess but to different degrees. Specific properties, such as detectors that measure nitrogen-phosphorous content, have limited applications but compensate for this by their increased sensitivity. Each detector has two main parts that when used together they serve as transducers to convert the detected property changes into an electrical signal that is recorded as a chromatogram.

The first part of the detector is the sensor which is placed as close the the column exit as possible in order to optimize detection.

Detection Systems

The second is the electronic equipment used to digitize the analog signal so that a computer may analyze the acquired chromatogram. The sooner the analog signal is converted into a digital signal, the greater the signal-to-noise ratio becomes, as analog signal are easily susceptible to many types of interferences. An ideal GC detector is distinguished by several characteristics. The first requirement is adequate sensitivity to provide a high resolution signal for all components in the mixture. This is clearly an idealized statement as such a sample would approach zero volume and the detector would need infinite sensitivity to detect it.

In modern instruments, the sensitivities of the detectors are in the range of 10 -8 to 10 g of solute per second. Furthermore, the quantity of sample must be reproducible and many columns will distort peaks if enough sample is not injected. An ideal column will also be chemically inert and and should not alter the sample in any way. In addition, such a column would have a short linear response time that is independent of flow rate and extends for several orders of magnitude. Moreover, the detector should be reliable, predictable and easy to operate. Understandably, it is not possible for a detector meet all of these requirements.

Type of Detector. Applicable Samples. Detection Limit. Mass Spectrometer MS. Tunable for any sample. Flame Ionization FID. Thermal Conductivity TCD. Electron-Capture ECD. Halogenated hydrocarbons. Atomic Emission AED. Chemiluminescence CS. Oxidizing reagent. Dark current of PMT. Photoionization PID. Vapor and gaseous Compounds.

Mass Spectrometer MS detectors are most powerful of all gas chromatography detectors. When the sample exits the chromatography column, it is passed through a transfer line into the inlet of the mass spectrometer. The sample is then ionized and fragmented, typically by an electron-impact ion source. During this process, the sample is bombarded by energetic electrons which ionize the molecule by causing them to lose an electron due to electrostatic repulsion.

Further bombardment causes the ions to fragment. Most ions are only singly charged. The Chromatogram will point out the retention times and the mass spectrometer will use the peaks to determine what kind of molecules are exist in the mixture. A simple quadrupole ion-trap consists of a hollow ring electrode with two grounded end-cap electrodes as seen in figure.

Ions are allowed into the cavity through a grid in the upper end cap. Ions that are too heavy or too light are destabilized and their charge is neutralized upon collision with the ring electrode wall. Emitted ions then strike an electron multiplier which converts the detected ions into an electrical signal. This electrical signal is then picked up by the computer through various programs. They are rugged, easy to use and can analyze the sample almost as quickly as it is eluted.

The disadvantages of mass spectrometry detectors are the tendency for samples to thermally degrade before detection and the end result of obliterating all the sample by fragmentation. Figure Arrangement of the poles in Quadrupole and Ion Trap Mass spectrometers. Flame ionization detectors FID are the most generally applicable and most widely used detectors. In a FID, the sample is directed at an air-hydrogen flame after exiting the column. At the high temperature of the air-hydrogen flame, the sample undergoes pyrolysis, or chemical decomposition through intense heating.

Pyrolized hydrocarbons release ions and electrons that carry current. A high-impedance picoammeter measures this current to monitor the sample's elution. It is advantageous to used FID because the detector is unaffected by flow rate, noncombustible gases and water. These properties allow FID high sensitivity and low noise.

The unit is both reliable and relatively easy to use. However, this technique does require flammable gas and also destroys the sample. Thermal conductivity detectors TCD were one the earliest detectors developed for use with gas chromatography. The TCD works by measuring the change in carrier gas thermal conductivity caused by the presence of the sample, which has a different thermal conductivity from that of the carrier gas.

Their design is relatively simple, and consists of an electrically heated source that is maintained at constant power. The temperature of the source depends upon the thermal conductivities of the surrounding gases. The source is usually a thin wire made of platinum, gold or. The resistance within the wire depends upon temperature, which is dependent upon the thermal conductivity of the gas. TCDs usually employ two detectors, one of which is used as the reference for the carrier gas and the other which monitors the thermal conductivity of the carrier gas and sample mixture.

Carrier gases such as helium and hydrogen has very high thermal conductivities so the addition of even a small amount of sample is readily detected. The advantages of TCDs are the ease and simplicity of use, the devices' broad application to inorganic and organic compounds, and the ability of the analyte to be collected after separation and detection.

The greatest drawback of the TCD is the low sensitivity of the instrument in relation to other detection methods, in addition to flow rate and concentration dependency. Schematic of thermal conductivity detection cell. Figure 13 represents a standard chromatogram produced by a TCD detector. Thermodynamic study of physical adsorption 8 1. The different models of adsorption 8 1. The Hill model 9 1. The Hill-Everett model 10 1.

Formulating the equilibrium 10 1. Isotherm equation 11 1. Thermodynamics of adsorption equilibrium in the Hill-Everett model 12 1. Physical adsorption isotherms 13 1. General points 13 1. Adsorption isotherms of mobile monolayers 15 1. Adsorption isotherms of localized monolayers 15 1. Thermodynamic method 16 1. The kinetic model 17 1. Multilayer adsorption isotherms 18 1. Isotherm equation 18 1. Chemical adsorption isotherms 23 1.

Bibliography 27 Chapter 2. Structure of Solids: Physico-chemical Aspects 29 2. The concept of phases 29 2. Solid solutions 31 2. Point defects in solids 33 2. Denotation of structural members of a crystal lattice 34 2. Formation of structural point defects 36 2.

Formation of defects in a solid matrix 36 2. Formation of defects involving surface elements 37 2. Concept of elementary hopping step 38 2. Bibliography 38 Chapter 3. Gas-Solid Interactions: Electronic Aspects 39 3. Introduction 39 3. Electronic properties of gases 39 3. Electronic properties of solids 40 3. Introduction 40 3. Energy spectrum of a crystal lattice electron 41 3. Reminder about quantum mechanics principles.

Band diagrams of solids 45 3. Effective mass of an electron 52 3. Electrical conductivity in solids 55 3. Full bands 55 3. Partially occupied bands 56 3. Influence of temperature on the electric behavior of solids 57 3. Band diagram and Fermi level of conductors 57 3. Case of intrinsic semiconductors 61 3. Case of extrinsic semiconductors 62 3.

Case of materials with point defects 64 3. Metal oxides with anion defects, denoted by MO1x 65 3. Metal oxides with cation vacancies, denoted by M1xO 66 3. Bibliography 68 Chapter 4. Interfacial Thermodynamic Equilibrium Studies 69 4. Introduction 69 4. Interfacial phenomena 70 4. Solid-gas equilibriums involving electron transfers or electron holes 71 4. Concept of surface states 72 4. Space-charge region SCR 73 4. Electronic work function 77 4. Case of a semiconductor in the absence of surface states 77 4. Case of a semiconductor in the presence of surface states 78 4. Influence of adsorption on the electron work functions 80 4.

8. Systems Integration and Interface Management

Influence of adsorption on the surface barrier VS 80 4. Influence of adsorption on the dipole component VD. Solid-gas equilibriums involving mass and charge transfers 91 4. Solids with anion vacancies 92 4. Solids with interstitial cations 94 4.

Solids with interstitial anions 94 4. Solids with cation vacancies 96 4. Homogenous semiconductor interfaces 97 4. The electrostatic potential is associated with the intrinsic energy level 4. Electrochemical aspect 4. Polarization of the junction. Heterogenous junction of semiconductor metals 4.

Bibliography Chapter 5. Model Development for Interfacial Phenomena 5. General points on process kinetics 5. Linear chain 5. Pure kinetic case hypothesis 5. Evolution of the rate according to time and gas pressure 5. Diffusion in a homogenous solid phase 5. Branched processes 5. Electrochemical aspect of kinetic processes 5. Expression of mixed potential 5. Bibliography Chapter 6. Apparatus for Experimental Studies: Examples of Applications 6.

Introduction 6. Calorimetry 6. General points 6. Theoretical aspect of Tian-Calvet calorimeters 6. Seebeck effect 6. Peltier effect 6. Tian equation 6. Description of a Tian-Calvet device 6. Thermogram profile 6. Examples of applications 6. Thermodesorption 6. Adsorption, ion exchange and chromatography are sorption processes in which certain adsorbates are selectively transferred from the fluid phase to the surface of insoluble, rigid particles suspended in a vessel or packed in a column. Pharmaceutical industry applications, which use adsorption as a means to prolong neurological exposure to specific drugs or parts thereof, [ citation needed ] are lesser known.

The word "adsorption" was coined in by German physicist Heinrich Kayser — The adsorption of gases and solutes is usually described through isotherms, that is, the amount of adsorbate on the adsorbent as a function of its pressure if gas or concentration for liquid phase solutes at constant temperature. The quantity adsorbed is nearly always normalized by the mass of the adsorbent to allow comparison of different materials.

To date, 15 different isotherm models have been developed. The first mathematical fit to an isotherm was published by Freundlich and Kuster and is a purely empirical formula for gaseous adsorbates:. Irving Langmuir was the first to derive a scientifically based adsorption isotherm in It is a semi-empirical isotherm with a kinetic basis and was derived based on statistical thermodynamics. Its the most common isotherm equation to use due to its simplicity and its ability to fit a variety of adsorption data.

It is based on four assumptions:. These four assumptions are seldom all true: there are always imperfections on the surface, adsorbed molecules are not necessarily inert, and the mechanism is clearly not the same for the very first molecules to adsorb to a surface as for the last. The fourth condition is the most troublesome, as frequently more molecules will adsorb to the monolayer; this problem is addressed by the BET isotherm for relatively flat non- microporous surfaces.

The Langmuir isotherm is nonetheless the first choice for most models of adsorption and has many applications in surface kinetics usually called Langmuir—Hinshelwood kinetics and thermodynamics.

Looking for other ways to read this?

Through its slope and y intercept we can obtain v mon and K , which are constants for each adsorbent—adsorbate pair at a given temperature. If we assume that the number of sites is just the whole area of the solid divided into the cross section of the adsorbate molecules, we can easily calculate the surface area of the adsorbent. The surface area of an adsorbent depends on its structure: the more pores it has, the greater the area, which has a big influence on reactions on surfaces.

Often molecules do form multilayers, that is, some are adsorbed on already adsorbed molecules, and the Langmuir isotherm is not valid. In Stephen Brunauer , Paul Emmett , and Edward Teller developed a model isotherm that takes that possibility into account. Their theory is called BET theory , after the initials in their last names.

Bestselling Series

They modified Langmuir's mechanism as follows:. The derivation of the formula is more complicated than Langmuir's see links for complete derivation. We obtain:. The key assumption used in deriving the BET equation that the successive heats of adsorption for all layers except the first are equal to the heat of condensation of the adsorbate. The Langmuir isotherm is usually better for chemisorption, and the BET isotherm works better for physisorption for non-microporous surfaces.

In other instances, molecular interactions between gas molecules previously adsorbed on a solid surface form significant interactions with gas molecules in the gaseous phases. Hence, adsorption of gas molecules to the surface is more likely to occur around gas molecules that are already present on the solid surface, rendering the Langmuir adsorption isotherm ineffective for the purposes of modelling. This effect was studied in a system where nitrogen was the adsorbate and tungsten was the adsorbent by Paul Kisliuk — in From here, adsorbate molecules would either adsorb to the adsorbent or desorb into the gaseous phase.

If the adsorbate molecule in the precursor state is in close proximity to an adsorbate molecule that has already formed on the surface, it has a sticking probability reflected by the size of the S E constant and will either be adsorbed from the precursor state at a rate of k EC or will desorb into the gaseous phase at a rate of k ES.

If an adsorbate molecule enters the precursor state at a location that is remote from any other previously adsorbed adsorbate molecules, the sticking probability is reflected by the size of the S D constant. These factors were included as part of a single constant termed a "sticking coefficient", k E , described below:.

As S D is dictated by factors that are taken into account by the Langmuir model, S D can be assumed to be the adsorption rate constant. Adsorption constants are equilibrium constants , therefore they obey the van 't Hoff equation :. As can be seen in the formula, the variation of K must be isosteric, that is, at constant coverage. If we start from the BET isotherm and assume that the entropy change is the same for liquefaction and adsorption, we obtain. The adsorption of ensemble molecules on a surface or interface can be devived into two processes: adsorption and desorption.

If the adsorption rate wins the desorption rate, the molecules will accumulate over time giving the adsorption curve over time. If the desorption rate is larger, the number of molecules on the surface will decrease over time.

About the Author

The adsorption rate is dependent on the temperature, the diffusion rate of the solute, and the energy barrier between the molecule and the surface. The diffusion and key elements of the adsorption rate can be calculated use Fick's laws of diffusion and Einstein relation kinetic theory.

The desorption of a molecule from the surface depends on the binding energy of the molecule to the surface and the temperature. Adsorbents are used usually in the form of spherical pellets, rods, moldings, or monoliths with a hydrodynamic radius between 0. They must have high abrasion resistance, high thermal stability and small pore diameters, which results in higher exposed surface area and hence high capacity for adsorption.

Physical Characteristics of Surfaces and Interfaces | Aalto University

The adsorbents must also have a distinct pore structure that enables fast transport of the gaseous vapors. It is prepared by the reaction between sodium silicate and acetic acid, which is followed by a series of after-treatment processes such as aging, pickling, etc. These after-treatment methods results in various pore size distributions.

Silica is used for drying of process air e. Zeolites are natural or synthetic crystalline aluminosilicates, which have a repeating pore network and release water at high temperature. Zeolites are polar in nature. The ion exchange process is followed by drying of the crystals, which can be pelletized with a binder to form macroporous pellets. Zeolites are applied in drying of process air, CO 2 removal from natural gas, CO removal from reforming gas, air separation, catalytic cracking , and catalytic synthesis and reforming.

Non-polar siliceous zeolites are synthesized from aluminum-free silica sources or by dealumination of aluminum-containing zeolites. This high temperature heat treatment breaks the aluminum-oxygen bonds and the aluminum atom is expelled from the zeolite framework. Activated carbon is a highly porous, amorphous solid consisting of microcrystallites with a graphite lattice, usually prepared in small pellets or a powder.

It is non-polar and cheap.